||| 中文站 || German | Japanese | Russian | French | English |Testing Machine Forum ||
 
 
Current Location: Home » News » Technical Articles » 正文

Needle flame tester | Needle flame tester manufacturers | imported needle flame tester

Increase font size  Decrease font size Date:2013-01-03  Views:3164
Core Tip:Needle flame tester | Needle flame tester manufacturers | imported needle flame tester Needle flame test is IEC60695 -11
Needle flame tester | Needle flame tester manufacturers | imported needle flame tester


Needle flame test is IEC60695 -11-5, GB/T5169.5-2008, GB4706.1-2005 and other standards require the use of a small flame ignition source simulation project.
AUTO-ZY Needle flame test apparatus is the required size (Φ0.9mm) of the needle burner, through a specific gas (butane) to 45 ° angle burning test facilities regularly targeted, depending on whether the ignition and hold test the length of time and fuel burning equipment to assess the internal fault conditions caused by the small flame of fire danger.
AUTO-ZY Needle flame test apparatus for lighting, low voltage electrical appliances, household appliances, electrical machines, motors, power tools, electronic equipment, electrical instruments, electrical connectors, accessories and other electrical and electronic equipment and parts, components, research, production and quality inspection departments, but also for insulation, plastic or other solid combustible materials industry.

Technical parameters:
1, needle burner: height greater than 35mm, stainless steel needles Φ0.9mm-Φ0.5mm
2 burner angle: 0 °, 20 °, 45 ° adjustable
3, Shi burning time :0-999999 .9 s ± 0.1s adjustable (usually selected as the 30s)
4, holding burning time :0-999999 .9 s ± 0.1s, auto record, manual pause
5, flame height: 12mm ± 1mm ??(with a height measurement apparatus)
6, Shi flammable gas: butane or propane purity greater than 95%
7, the temperature measuring range: 0 ~ 1000 ℃
8, the flame temperature requirements: from 100 ℃ ± 2 ℃ 700 ℃ ± 3 ℃ rise time at 23.5 seconds ± 1 seconds
9, thermocouple: K-type Φ0.5mm accuracy of ± 0.05%.
10, test background: black background
11, the testing process: automatic control testing procedures, independent ventilation
12, reference standard: IEC60695 -11-5, GB/T5169.5-2008, GB4706.1-2005
13, studio size: greater than 0.5 cubic meters (0.75 according to customer requirements or 1 cubic cubic)
14, equipment, dimensions: 1100mm wide × 700mm deep × 1300mm high
15, control: the use of single-chip micro-computer and touch screen controls, high-precision thermometer stand-alone electronic control systems, anti-interference ability.
17, the operating efficiency: experimental control process to achieve one-button operation, fast and efficient testing.
18, the test standard integration: based on the actual test process writing test procedures
19, automatic: automatic ignition.
 
 
[ NewsSearch ]  [ ]  [ Tell a friend ]  [ Print this article ]  [ Close window ]

 

 
Recommended Graphic
Recommend News
Click Ranking
 
Contact QQ:1006931501*苏ICP备11049648号-15苏州亚诺天下仪器有限公司 版权所有
+86 18915433994
Buy pulling machine, preferred Coors brand! Contact Us | YANUO Group | Back Home【Service Hotline:+86 512 68559199】