Detailed parameters:
Model Specification |
UTM100 |
UTM300 |
UTM600 |
UTM1000 |
UTM2000 |
||
Maximum test force(kN) |
100 |
300 |
600 |
1000 |
2000 |
||
Control mode |
Y type: microcomputer control |
||||||
Showing the value of the relative error of the maximum allowable value |
±1% |
||||||
Test force measurement range(kN) |
1%—100% |
||||||
Stress rate control range |
1MP/S-60MP/S |
||||||
Displacement rate control range |
0.5㎜/min-50㎜/min |
||||||
The trial strain rate adjustment range |
0.00025/S-200025/S |
||||||
Maximum tensile space(mm) |
560 |
620 |
690 |
620 |
700 |
||
Maximum compression space(mm) |
530 |
550 |
620 |
580 |
600 |
||
Round specimen clamping diameter(mm) |
Φ6~Φ22 |
Φ10~Φ32 |
Φ13~Φ40 |
Φ14~Φ45 |
Φ20~Φ70 |
||
Flat plate specimen thickness(mm) |
0~15 |
0~15 |
0~30 |
0~40 |
0~50 |
||
The bending fulcrum largest spacing(mm) |
400 |
400 |
600 |
600 |
600 |
||
Shearing specimen(mm) |
Φ10 |
||||||
Both sides of the pillar spacing(mm) |
460 |
495 |
570 |
600 |
580 |
||
Total power(kW) |
1.2 |
2 |
2.1 |
2.1 |
6 |
||
Dimensions (mm) (L × W × H) |
Host computer |
700×450× 1780 |
800×500× 1950 |
950×630× 2265 |
980×650× 2220 |
1200×850× 2900 |
|
Console |
1100×600×860 |
||||||
Net weight(kg) |
1500 |
2000 |
2500 |
3300 |
5500 |