Standard vertical burning tester for a V-0, V-1, V-2, HB, 5V of the VMT grade material combustible grading assessed. Research, production and quality control departments for lighting equipment, low voltage electrical appliances, household appliances, electrical machines, motors, power tools, electronic equipment, electrical instruments, electrical fittings and accessories such as electric and electronic products and their component parts, also applies insulation, plastic or other solid combustible materials industries.
Standard:
Meet the the IEC60950, UL94, IEC707, IEC60695-11-10/-20, ISO1210, GB/T5169.16 and 17, GB4943, GB/T2408-1996 standard specifies the analog security test project.
Basic principles:
When the product around the fire, you should ensure that will not cause a fire to spread. The required size of the Bunsen burner (Bunsen burner) and specific gas source (methane, or natural gas), certain flame height and certain facilities flame angle of the test was horizontal or vertical timing facilities burning several times to try Commodities ignited, hot combustion duration and burn length to assess its flammability and the risk of ignition.
Main features:
Tester from the test section and control section uses the integrated design, easy on-site installation and commissioning. The test chamber housing and the important parts are made of stainless steel, resistant smoke, gas corrosion.
High degree of automation of the control system with automatic ignition during the test is the test product to automatically follow the flame function in both vertical and horizontal directions. The temperature and time of the digital display, observed and recorded convenient, reliable use.
U-tube differential manometer (Dwyer), with U.S. imports placed directly on the surface of the device, convenient and aesthetic, easy to operate.
For the convenience of a single operation, configuration-wire switch can automatically control the trial began, afterflame time, I blanch time.
Bunsen burner burning lamp can be adjusted 0-45 degrees angle, and with the corresponding angle indication.
Using standard explosion-proof lamps, lighting experiment warranty does not communicate with the outside world, in line with standard experimental requirements.
With a level of combustion fixture, vertical burning fixture and the flexible the test fixture, The flexible clamp made of high quality rail can be up and down, back and forth, left and right adjustment.
Automatic or manual control, several tests can guarantee continuous automatic
Using imported ammeter, time relays and counters, and other components of domestic brand-name
The main performance parameters:
Project Name
|
The main parameters
|
Bunsen burner lamp
|
Diameter of 9.5mm ± 0.5mm length of about 100mm from the air inlet up
|
Specimen
|
Length of 125 ± 5mm, width of 13.0 ± 0.5 mm, a thickness of less than 13mm
|
Burner angle
|
0~45°(Manual adjustment with scale)
|
Shi gases
|
98% methane standard gas or natural gas or propane 37MJ/m3 ± 1MJ/m3
|
The Gas flame temperature gradient
|
From 100 ℃ ± 2 ℃ ~ 700 ℃ ± 3 ℃ with 23.5s ± 1.0s or in accordance with the requirements of customized standard (the required temperature calibration device authentication)
|
Test time and holding burning time
|
1s~999.9s(Digital Display can be preset)
|
Facilities burning Views repeatedly
|
1~9999次(Digital Display can be preset)
|
Temperature calibration verification device (optional)
|
Imported instruments automatic control or manual stopwatch control, with φ4mm, 0.58 ± 0.01g standard copper head
|
Temperature calibration verification using a thermocouple (optional)
|
Ø0.5mm, K-type, imported insulated high temperature resistant armored thermocouple
|
Input power
|
220V/50~60HZ/500VA
|
Dimensions
|
0.75 cubic models: 650mm × height × depth, width 1325mm 1320mm
|
The box size
|
Width 1060mm ×Deep 647mm × high 1150mm
|
Vent
|
Ø100mm
|