Scope: glow-wire test apparatus for lighting, low voltage electrical equipment, household appliances, electrical machines, motors, power tools, electronic equipment, electrical instruments, IT equipment, electrical business equipment, electrical connectors and accessories and other electrical and electronic products their research, production and quality control departments component parts, but also for insulation, plastic or other solid combustible materials industry;
Standard: glow-wire test is IEC60695-2-10: 2000 ~ IEC60695-2-13: 2000 "Glowing / hot, the basic test methods, glow-wire test apparatus and common test procedure" and GB4706.1 and GB / T5169, standard UL746A, IEC829, DIN695, VDE0471 such as the use of non-flame ignition source simulation project;
Rationale: glow-wire test apparatus will provide material (Ø4 Ni80 / Cr20) and the shape of the electric wire with a large current is heated to the test temperature (550 ℃ ~ 960 ℃) 1min after a predetermined pressure (1.0N) vertical scalding test 30s, depending on whether the test product and bedding ignition or time to determine who fired the finished electrical and electronic equipment fire risk; Determination of solid insulating materials and other solid combustible materials from flammable, ignition temperature (GWIT), flammability and Flammability index (GWFI);
Main features: glow-wire test instrument using the chamber portion and the control portion integrated design, easy on-site installation and commissioning. Chamber shell and an important component of stainless steel, anti-smoke, gas corrosion; using energy-efficient regulator manually adjust the test current, achieve precise temperature control purposes; time, temperature digital display, easy to observe and record, the use of stable and reliable.
The main parameters:
Glow-wire Ø 4mm ± 0.04mmNi / Cr (80/20) special Standard Circular, horizontal standing;
Thermocouple Ø0.5mmK type, imported high-temperature insulation type sheathed thermocouple, armor sets Heat 1100 ℃ (better than the standard 1050 ℃);
Electrically heated glow wire temperature 500 ℃ ~ 1100 ℃, temperature fluctuations ± 5 ℃, the instrument accuracy: 0.5
Test for glow-wire test pressure 1.0N ± 0.1N (adjustable) (better than standard 1.0N ± 0.2N);
The maximum depth of the hot 7mm ± 0.5mm;
Sample moving speed 10mm / s ~ 25mm / s;
Test time 30s ± 0.1s (Omron H5CN-XAN-Z digital timer can be preset 0.1-99.99S adjusted)
Controlling party time relay
Ordinary AC motor drive motor
Ignited bedding thickness 10mm thick white pine planks, covered 12g / m2 ~ 30g / mm2 standard tissue paper, from under the glow-wire 200mm ± 5mm;
Test area volume ≥0.5m3 black background, background illumination ≤20Lx;
Dimensions W1100mm × D600mm × H1220mm, vent Ø100mm;
Power supply power 1kVA 220V 50-60Hz